Customization: | Available |
---|---|
After-sales Service: | 160+ After-Sales Service Stations Worldwide |
Warranty: | 1 Year or 1000 Hours of Running |
Still deciding? Get samples of US$ 159999/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
About our WANDING GENSET
Hunan Wanding Intelligent Technology Co.,Ltd
Hunan Wanding Intelligent Technology Co., Ltd. was established in 2019. its affiliated unit is [Changsha Wanding Electromechanical Equipment Co., Ltd.] established in 2009.
25 years we only focus on one thing - to bring the most worry-free solutions for customers who need electricity, not just the production and sales of diesel generator sets, as the largest genset factory in central China our company is a manufacture integrating design, manufacturing, installation, environmental protection and noise reduction, sales and technical services..
With modern production technology, excellent manufacturing technology, perfect quality management system, and professional after-sales service team, We have received accolades from customers all over the world.
Product Description
Wanding YC DIESEL series, the engine is produced by Guangxi Yuchai Ship Electric Power Co., Ltd. The engine body and other main structures have been tested for a long time, China's local comprehensive performance - the most cost-effective power brand , product cover power range 20KVA~3750KVA.
The cylinder head is made of high-quality alloy cast iron to ensure the high reliability of the whole machine. Optimized and verified by YC DIESEL's advanced combustion development technology, it has the characteristics of energy saving, environmental protection, high reliability, strong loading capacity and good maintainability. The structure of one cylinder and one cover has a maintenance window on the side of the machine body, which is convenient for maintenance.
Optional Types
Welcome to Customize
WANDING YC DIESEL series main technical parameter list (T3) | |||||||||||
YC DIESEL series |
Unit power KW |
Diesel model | Diesel power prime/stand-by KW |
Number of cylinder |
Bore*Stroke | Total displacement (L) |
Minimum Fuel Extinction Rate g/(kW.h) |
Oil capacity(L) |
Compression ratio | Weight (kg) | Unit Dimensions (mm) |
WD-16 | 16 | 4D24G6 | 18. 5/20.4 | 4 | 87*103 | 2.45 | 232 | 9.5 | 19:1 | 450 | 1650*630*1100 |
WD-20 | 20 | 4D24G7 | 23/25. 4 | 4 | 87*103 | 2.45 | 232 | 9.5 | 19:1 | 500 | 1650*630*1100 |
WD-25 | 25 | YCDV254FHZ-35 | 25/27. 5 | 4 | 89*100 | 2. 50 | 205 | 9.5 | 17.5:1 | 500 | 1650*630*1000 |
WD-50 | 50 | YC4D90-D34 | 60/66 | 4 | 108*115 | 4.214 | 205 | 13 | 17.5:1 | 746 | 1850*700*1200 |
WD-110 | 110 | YC4A190-D30 | 125/138 | 4 | 108*132 | 4.84 | 210 | 14 | 16:1 | 1200 | 2500*900*1400 |
WD-150 | 150 | YCD6Q33H6-260 | 190/209 | 6 | 108*135 | 7.5 | 205 | 21 | 16:1 | 1350 | 2450*910*1300 |
WD-200 | 200 | YCA08350-D30 | 235/259 | 6 | 110*132 | 7. 53 | 205 | 20 | 17.5:1 | 1875 | 2860*1040*1530 |
WD-250 | 250 | YC6MK420-D30 | 281/309 | 6 | 123*145 | 10. 34 | 195 | 30 | 16.8:1 | 2244 | 2940*1100*1550 |
WD-300 | 300 | YC6MJ500-D30 | 334/367 | 6 | 131*145 | 11.73 | 205 | 30 | 16.8:1 | 2285 | 3000*1130*1570 |
WD-350 | 350 | YC6K600-D30 | 401/441 | 6 | 129*165 | 12. 94 | 205 | 32 | 17.5:1 | 3000 | 3150*1280*1750 |
WD-400 | 400 | YC6K660-D30 | 441/485 | 6 | 129*165 | 12. 94 | 205 | 32 | 17.5:1 | 3000 | 3150*1280*1750 |
WD-500 | 500 | YC6TD840-D31 | 561/616 | 6 | 152*180 | 19.6 | 195 | 52 | 14:1 | 3920 | 3600*1500*1870 |
WD-600 | 600 | YC6TD900-D31 | 605/665 | 6 | 152*180 | 19.6 | 195 | 52 | 14:1 | 4130 | 3600*1470*1900 |
WD-800 | 800 | YC12VTD1350-D30 | 900/990 | 12 | 152*180 | 39.2 | 205 | 210 | 14:1 | 9000 | 4500*1700*2400 |
WD-900 | 900 | YC12VTD1500-D30 | 1000/1100 | 12 | 152*180 | 39.2 | 205 | 210 | 14:1 | 9000 | 4500*1700*2400 |
WD-1000 | 1000 | YC12VTD1680-D30 | 1120/1230 | 12 | 152*180 | 39.2 | 205 | 210 | 14:1 | 11000 | 5500*1800*2400 |
*Emergency Standby Power (ESP)
This generator rating is normally used for equipment that is connected to a commercial power utility but used to provide emergency power when that utility suffers an outage. The rating represents the maximum amount of power a generator set can deliver. The average load factor is set by the manufacturer but is usually 70% of full capacity, and there is no overload capability. ESP-rated generators may run for a maximum of 200 hours per year under Environmental Protection Agency emissions regulations.
*Prime Power (PRP)
This generator set rating is normally applied to generators used without a connection to a commercial power utility. Typical applications include temporary use, load management, or to power off-grid locations such as wilderness outposts and remote mining, quarrying, or drilling operations. The average load factor is usually 70% of full capacity, but unlike an ESP-rated generator, a PRP-rated engine can run for an unlimited number of hours. A 10% overload capacity is permissible for short periods of time (a maximum of one hour per 12 hours, and a cap of 400 hours per year).
Service and Warranty
Sales Promise: Wanding Genset offers a full line of new, high quality products. Each unit undergoes rigorous factory testing.
Warranty: Under our standard terms: one year from the time you receive the goods, or 1000 hours of running (whichever comes first).
Service and parts are available from Wanding Genset or from your local dealer.
Technical Consulting Service: 7X24 hours online technical service consultation and highly customized service are supported.